Coaxial cable RC-ANT-024

Key specifications
Impedance50 Ω
VSWR≤ 1.5
JacketPVC
Cut-off frequency8.8GHz
Peak power rating40kW
PIM- 160dBc@2X20W
Length20M ( Or Customized)

Specifications

Inner ConductorCopper Clad Aluminum Wire4.8
DielectricPhysical Foam Polyethylene12.3
Outer ConductorCorrugated Copper Tube13.8
JacketBlack PE15.7
Electrical Characteristics
Capacitance (pF/M)76
Impedance (Ohm)50
Velocity of Propagation (%)88
Peak Power Rating (KW)40
RF Peak Voltage (KV)1.6
Insulation Resistance (MΩ.km)>5000
Cut-off Frequency (GHz)8.8
Insulation Voltage (KV)6
Inner Conductor DC Resistance (Ω/km)1.48
Outer Conductor DC Resistance (Ω/km)1.90
Jacket Spark (KV)8.0
Shielding Effectiveness (dB)>120
VSWR≤(Return loss≥dB)
0.005-3GHz1.15 (23)
0.8-1.0GHz1.10 (26)
1.7-2.0GHz1.10 (26)
2.0-2.4GHz1.10 (26)
Mechanical and Environmental Characteristics
Min. Single Bending Radius (mm)50
Min. Repeated Bending Radius (mm)125
No. of Bends15
Mobile Apply (mm)350
Bending Moment (N.m)5.0
Tensile Strength (kg)110
Storage Temp (°C)-55 to +85
Installation Temp (°C)-40 to +60
Operating Temp (°C)-55 to +85
Attenuation (VSWR1.0, cable temp. 20°C) & Average Power (VSWR 1.0, ambient temp. 40°C)
Frequency (MHz)Attenuation (≯dB/100m)Average Power (KW)
1002.153.94
2003.082.75
4504.701.80
8006.351.33
9006.751.25
10007.201.18
15009.050.95
18009.900.86
200010.500.81
220011.100.77
240011.600.75
250011.950.73
300013.200.65

Description

1/2 Foam Dielectric Electric Feeder coaxial cable features a 5 in bending radius that prevents kinking. This coaxial cable has an annular corrugated copper outer conductor and a copper-clad aluminum center conductor. Maximum frequency capacity is 8.8 GHz.

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.

We use these details only to answer your request. Privacy policy