Digital fibre DAS, VHF 151–153 / 161–163 MHz, 33 dBm RC-DAS-021

Key specifications
150MHz Frequency Range151-153MHz / 161-163MHz
Device Gain50 ±2dB
Device Output powerUL: -10± 2 dBm, DL: 33 ± 2 dBm
RF connectorN/Female
Power customization2–20Watt

Installation needs the agreement of the operator of each network carried (mobile operators, TETRA radio network): in Belgium and most other EU countries, a repeater or DAS may only carry a network with that consent. We deliver for projects where this agreement is in place. While it is being requested we can quote, and we prepare with you the technical information each operator asks for (bands, gain, output power, location).

Specifications

ParameterMaster Unit (MU)Remote Unit (RU)
Frequency RangeUplink: 161~163MHz (adjustable) Downlink: 161~163MHz (adjustable)
Maximum Input Power (Non-Destructive)10 dBm
Transmission Distance≤ 20km
Maximum RF Output Power-10±2dBm (UL)33±2dBm (DL)
Number of Units1≤ 16
Maximum Gain (Cable Access)50±2dB
Gain Adjustment Range1~25 dB @ step of 1 dB
VSWR≤ 1.6
Noise Figure≤ 5dB (Only for Uplink)
In-band Ripple≤3.5dB
Spurious Emission≤ -36dBm
Third-Order Inter-Modulation≤ -45dBc / 30kHz
System Delay≤21 μs
I/O Impedance50Ω
Connector - RF1Xn-Female1xN-Female
Connector - Optic8X FC/APC1X LC/UPC
Fiber Optical TypeSingle Mode
Optical Output Power≥-9dBm
Optical Receiver Sensitivity≤-20dBm
Temperature RangeOperation: -25°C ~ + 55°C
Relative Humidity Range≤ 95% (non-Condensing)
Power SupplyAC 220V±44V/50±5Hz
ApplicationIndoor (IP20)Indoor or Outdoor (IP65)
Dimensions330*425*44mm (19"1U)450*335*180mm
Weight8 kg20 kg

Features

  • Optical-to-Electrical (O/E) Converter: Converts incoming optical signals to electrical signals.
  • Optical transmission up to 10km (max.)

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.