Fibre DAS, 33 dBm RC-PS-009

Key specifications
UHF Frequency Range380-470MHz
Device Gain50 ±2dB
Device Output powerUL: -10± 2 dBm, DL: 33 ± 2 dBm
RF connectorN/Female
Power customization2–20Watt

Installation needs the agreement of the operator of each network carried (mobile operators, TETRA radio network): in Belgium and most other EU countries, a repeater or DAS may only carry a network with that consent. We deliver for projects where this agreement is in place. While it is being requested we can quote, and we prepare with you the technical information each operator asks for (bands, gain, output power, location).

Specifications

Duplex Frequency Range380-470MHz
Operational Bandwidth0.2-5MHz
Maximum Gain (UL/DL)40/40+3 dB
Pass Band Ripple< +2dB
Optical Output Power-6dBm+2dB @1550nm
Optical Receiver Sensitivity> -15dBm
Uplink Output Power23dBm + 2dB
Manual Gain Control0 - 31dB @1dB step
Auto Level Control> 20dB
Group Delay Time< 1.5μs
VSWR< 1.5
Noise Figure< 6dB (uplink, with 1RU)
IMD3> 45dBc
Connector1*N-female, 8*LC/UPC duplex
Local ControlLCD+Keypad, WiFi, RJ45
OMC (Optional)LTE Modem
Approx. Weight10kg
Operating Temperature-10 to + 55°C
ApplicationsIndoor (IP40)
Humidity5% to 95%
MTBF> 50,000 hours
InstallationRack mount
DimensionStandard 2U (19" rack)
Duplex Frequency Range380-470MHz
Operational Bandwidth0.2-5MHz
Maximum Gain (UL/DL)45/40+3 dB
Auto Gain Control Range31dB
Pass Band Ripple< +2dB
Optical Output Power3dBm+2dB @1310nm
Optical Receiver Sensitivity> -15dBm
Uplink Output Power33dBm + 2dB
Auto Gain Control0 - 31dB @1dB step
Auto Level Control> 20dB
Group Delay Time< 1μs
VSWR<1.5
IMD3 (2X37dBm)< 45dBc
Connector1*N-female, 1*LC/UPC
Local ControlLCD+ Keypad, WiFi or RJ45
OMC (Optional)Through MU via fiber
Approx. Weight10kg
Operating Temperature-10 to + 55°C
ApplicationsIndoor & outdoor (IP65)
Humidity5% to 95%
MTBF> 50,000 hours
InstallationWall mount
Dimension (without connector)385mm*307mm*204mm

Features

  • Optical-to-Electrical (O/E) Converter: Converts incoming optical signals to electrical signals.

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.

We use these details only to answer your request. Privacy policy