Rays CoverageCellular repeaters

Tri-band repeater, 900 / 1800 / 2100 MHz, 27 dBm RC-REP-116

Key specifications
RF Connect TypeN/Female Connector
AGC Intelligent functionYes,31dB @ 1dB/ Step
900MHz Range890-915MHz/935-960MHz
Size48x46x18cm+52x21x16cm,8.5kg
Lightning ProtectionWith Lightning Protection
1800MHz Range1710-1785MHz/ 1805-1880MHz
2100MHz Range1920-1980MHz/ 2110-2170MHz
Gain80dB
Output power27dBm

Installation needs the agreement of the operator of each network carried (mobile operators, TETRA radio network): in Belgium and most other EU countries, a repeater or DAS may only carry a network with that consent. We deliver for projects where this agreement is in place. While it is being requested we can quote, and we prepare with you the technical information each operator asks for (bands, gain, output power, location).

Specifications

SpecificationsParameters
Frequency Range (options)Uplink890-915MHz,1710-1785MHz,1920-1980MHz
Downlink935-960MHz, 1805-1880MHz,2110-2170MHz
Frequency Bandwidth (3dB Bandwidth)25MHz&75MHz&60MHz
Gain80dB
Manual gain control (step attenuation)31dB @ 1dB/ Step
Auto Gain Control20dB Min.
Output Power (options)27dBm
9kHz~1GHz: ≤ -36dBm/30kHz
1GHz~12.75GHz: ≤ -30dBm/30kHz
Inter-Modulation Attenuation ACPR≤ -40dBc / 30kHz (measured under rated output power)
In-band Ripple≤ 3dB
VSWR<=2
I/O Impedance50 Ω
Noise Figure≤ 5dB
System Delay≤ 5μs
RF Connector (options)N(Female)
Operating TemperatureOperation: - 10°C ~ + 55°C / Storage: -20°C ~ +60°C
Power SupplyAC 110~220V±20%, 50/60Hz(AC 220V/ DC5V/2A power adapter)
Dimensions165*130*40 (mm)
Weight≤0.8 kg(Net)
Transmission Medium:Cable

Description

This is done through some complex circuitry that works through the use of external power and boosts the signal to usable levels.

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.

We use these details only to answer your request. Privacy policy