Rays CoverageCellular repeaters

Tri-band digital band-selective repeater, 900 / 1800 / 2100 MHz, 33 dBm RC-REP-191

Key specifications
900MHz Frequency Range890–910MHz/ 935–955MHz
1800MHz Frequency Range1745–1765MHz/1840–1860MHz
2100MHz Frequency Range1920–1935/2110–2125MHz; 1935-1950/2125-2140MHz
Bandwidth 900MHz&1800MHzSupports 1 Subband From 0.2 To 20 MHz Adjusted
Bandwidth 2100MHzSupports 2 Subband From 0.2 To 15 MHz Adjusted
Cellular Networks2G 3G 4G, Voice
RF Connector (options)N -Type (Female)

Installation needs the agreement of the operator of each network carried (mobile operators, TETRA radio network): in Belgium and most other EU countries, a repeater or DAS may only carry a network with that consent. We deliver for projects where this agreement is in place. While it is being requested we can quote, and we prepare with you the technical information each operator asks for (bands, gain, output power, location).

Specifications

SPECIFICATIONSPARAMETERS
Frequency Range900MHzUL890–910MHz, DL935–955MHz
1800MHzUL1745–1765MHz, DL1840–1860MHz
2100MHzUL1920–1935MHz, DL2110–2125MHz
2100MHzUL1935–1950MHz, DL2125–2140MHz
Bandwidth900MHzsupports 1 subband from 0.2 to 20 MHz adjusted
1800MHzsupports 1 subband from 0.2 to 20 MHz adjusted
2100MHzsupports 2 subband from 0.2 to 15 MHz adjusted
RF Carriers ARFCN FilteringDigital
GainUL: 75±3 dB DL: 80±3dB
Output PowerUL: 20±2dBm DL: 33±2dBm
Automatic Gain Control30dB/1dB
Minimum Input power≥ -90dBm
Gain Flatness / PB Ripple< 4dB
Automatic Level Control≥ 25dB
EVM≤8
VSWR≤1.8
Noise Figure≤8dB
Delay≤10μs
RF Connector (options)N -Type (Female)
Storage temperature range-40°C to +85°C
Operating Temperature-25°~+55°
Power Supply195-265 VAC
Barometric pressure55 kPa -106 kPa
Environment ConditionsIP65
Relative humidity5% - 95%
Weight≤20kg
Size596 x 400 x 203.5 mm

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.

We use these details only to answer your request. Privacy policy