Key specifications
900MHz frequency range880-915MHz; 925-960MHz
Bandwidth35MHz; Supports From 0.2 To 20MHz Bandwidth Adjusted
GainUL: 65dB; DL: 70dB
Output Power (options)UL: 15dBm; DL: ≥17dBm
Dimensions234*230*52mm

Installation needs the agreement of the operator of each network carried (mobile operators, TETRA radio network): in Belgium and most other EU countries, a repeater or DAS may only carry a network with that consent. We deliver for projects where this agreement is in place. While it is being requested we can quote, and we prepare with you the technical information each operator asks for (bands, gain, output power, location).

Specifications

RC-REP-188900 MHz
Frequency RangeUplink880-915MHz
Downlink925-960MHz
Number of Sub-Bands1 Sub-Band
Bandwidth35MHz, each Sub-Band support (0.2 - 20 MHz adjustable)
Max GainUplink65dBm
Downlink70dBm
Manual Gain Control31 dB in step of 1 dB
Automatic Gain Control≥ 20 dB
Gain Flatness≤ ±2 dB (peak-to-peak)
Max. Input Power Without Damage0 dBm
Output PowerUplink17 ±2dBm
Downlink20 ±2dBm
Spurious Emission9kHz~1GHz≤ -36dBm
1GHz~12.75GHz≤ -30dBm
ACPR±20MHzUplink≤-36dBc/Downlink≤-45dBc
±40MHzUplink≤-45dBc/Downlink≤-50dBc
EVM≤ 8
Frequency Stability≤ ±0.01 ppm
Noise Figure≤ 8 dB
VSWR≤ 2
Group Delay≤ 3 μs
RF ConnectorN-Female
Impedance50 Ω
Power SupplyInput: AC 100~240 V; Output: DC 5 V/ 5 A
Dimensions234*230*52mm
Weight≤ 5 Kg
IP RatingIP40
Operating Temperature-25 °C to 55 °C
Control & MonitoringLocalWIFI/Type-C port
RemoteOptional

Description

The repeater makes the signal stronger in places with poor signal coverage such as:

1) Underground areas: basements, parking lots, tunnels;

2) Other places where cellular signal is shielded by metal or concrete walls: offices, supermarkets, cinemas, hotels;

Figures are those stated for the standard model. Bands, power and options can differ per build: for your project we confirm them in a written build specification, and every unit ships with its own test record. Datasheets are available on request.

Quote request

Request a quote

The product family, the bands and the power class are enough for a first quote; a quantity range helps us prepare it.

Planning a product line under your own brand? Use the OEM / ODM form.

  • A quote for the products you name
  • The datasheets of the models in the quote
  • The list of what we still need from you, such as the band plan or site details

You can attach a band plan, drawings or a bill of materials here, or send them by email later.

Name and work email are required.

Reply within two working days.

We use these details only to answer your request. Privacy policy